Abstract
The ABB 1SVR040006R0100 represents a sophisticated solution for precision current measurement and signal conditioning in industrial automation environments. As part of ABB’s CC-U series of universal signal converters, this device provides three-way electrical isolation, configurable input/output ranges, and robust performance in demanding industrial settings. This technical analysis examines the specifications, applications, compatibility considerations, and alternative solutions for engineers and system integrators working with current measurement systems.
1. Product Overview
1.1 Basic Description
The ABB 1SVR040006R0100 is a universal RMS current converter designed for DIN rail mounting in industrial control cabinets. This device converts current signals into standardized output signals while providing complete electrical isolation between input, output, and power supply circuits.
Key Identification:
– Manufacturer: ABB
– Part Number: 1SVR040006R0100
– Series: CC-U/I
– Description: Universal signal converter 24-48VDC / 24VAC 50/60Hz
1.2 Primary Applications
- Motor current monitoring in industrial drives
- Power quality analysis in electrical distribution systems
- Battery management systems for renewable energy storage
- Process control instrumentation in manufacturing plants
- Building automation systems for energy management
2. Technical Specifications
2.1 Electrical Characteristics
Input Parameters:
– Input Range: 0 → 5 A AC/DC
– Frequency Range: 0 → 600 Hz
– Waveform Compatibility: Any waveform including DC, sinusoidal, triangular, phase-angle controlled
– Dual Range Selection: 0-1 A and 0-5 A via terminal configuration
Output Parameters:
– Voltage Output: 0 → ±11 V
– Current Output: 0 → ±55 mA
– Configurable Ranges: 41 output signal ranges (8 standard + 33 non-standard)
Power Supply:
– Rated Control Supply Voltage: 24 V AC (24-48 V DC compatible)
– Power Consumption: Approximately 2 W
– Supply Indication: Green LED for applied supply voltage
2.2 Performance Metrics
- Accuracy: ±0.5% of full-scale
- Response Time: 150 ms
- Isolation: 3-way electrical isolation (input/output/supply)
- Temperature Range: -20°C to +60°C operating ambient
- Short-Circuit Protection: Short-circuit proof signal outputs
2.3 Mechanical Specifications
- Dimensions: 105 mm (H) × 22.5 mm (W) × 120 mm (D)
- Mounting Type: DIN Rail (TS35/7.5 or TS35/15)
- Weight: 0.126 kg net weight (0.154 kg packaged)
- Terminal Type: Plug-in connecting terminals with unambiguous markings
- Enclosure: Standard industrial housing with IP20 rating
2.4 Configuration Features
- Lateral DIP Switches: 8 directly accessible switches for input/output configuration
- Adjustment Elements:
- Front-face potentiometer for gain adjustment (±5%)
- Front-face potentiometer for offset adjustment (±5%)
- Fail-Safe Configuration: Selectable detection of input voltage signal interruption (low/high fail-safe)
3. Compatibility Information
3.1 System Integration
Control System Compatibility:
– Programmable Logic Controllers (PLCs): Siemens, Allen-Bradley, Schneider Electric, Mitsubishi
– Distributed Control Systems (DCS): ABB, Emerson, Honeywell, Yokogawa
– Supervisory Control and Data Acquisition (SCADA): Compatible with major platforms
Communication Protocols:
– Analog Signal Standards: 4-20 mA, 0-10 V, ±10 V
– Digital Interfaces: Compatible with analog input modules
– Fieldbus Integration: Can interface with Profibus, Modbus, DeviceNet through appropriate converters
3.2 Environmental Compatibility
Standards Compliance:
– IEC 61131-2: Equipment requirements and tests for programmable controllers
– EN 50178: Electronic equipment for use in power installations
– CAN/CSA C22.2 No.14 & No.213: Industrial control equipment standards
– UL 508 & UL 1604: Industrial control equipment safety standards
– IEC/EN 61000-6-2/6-4: EMC standards for industrial environments
– RoHS Directive: Compliant with EU Directive 2011/65/EU
Installation Requirements:
– DIN Rail Specification: IEC/EN 60715 compliant rails (35 × 7.5 mm or 35 × 15 mm)
– Clearance Requirements: Minimum 50 mm above and below device for heat dissipation
– Wiring Specifications: 0.5-2.5 mm² wire size for terminal connections
– Grounding: Proper functional ground connection required via DIN rail or separate ground wire
3.3 Signal Compatibility
Input Signal Types:
– DC Current: Pure DC signals with superimposed AC components
– AC Current: Sinusoidal, non-sinusoidal, distorted waveforms
– Complex Waveforms: PWM signals, phase-controlled currents, harmonic-rich currents
Output Signal Types:
– Voltage Output: 0-±11 V with high impedance load (>1.0 kΩ)
– Current Output: 0-±55 mA with low impedance load (<500 Ω)
– Custom Ranges: 33 non-standard ranges configurable via DIP switches
4. Application Guidelines
4.1 Installation Procedure
Step 1: Mechanical Mounting
1. Secure DIN rail to control panel backplate according to IEC 60715 specifications
2. Hook top edge of converter onto DIN rail
3. Press bottom edge until device snaps securely into place
4. Verify mechanical stability and proper alignment
Step 2: Electrical Connections
1. Input Connections: Connect current-carrying conductor to terminals J/H (positive) and G (negative)
2. Output Connections:
– Voltage output: Terminals A (+) and C (-)
– Current output: Terminals D (+) and F (-)
3. Power Supply: Connect 24 V AC/DC to terminals K (L+) and M (L-)
4. Grounding: Ensure proper ground connection via DIN rail or separate ground terminal
Step 3: Configuration Setup
1. Select input range using terminal connections (0-1 A or 0-5 A)
2. Configure output signal range using lateral DIP switches (positions 1-8)
3. Set fail-safe mode according to system requirements
4. Connect monitoring equipment to output terminals
Step 4: Calibration Process
1. Apply lowest input signal (0 A or minimum expected current)
2. Adjust offset potentiometer for desired minimum output
3. Apply highest input signal (5 A or maximum expected current)
4. Adjust gain potentiometer for desired maximum output
5. Repeat process until desired accuracy is achieved
4.2 Operational Best Practices
System Integration Recommendations:
1. Signal Integrity:
– Use twisted-pair shielded cables for input connections
– Maintain minimum 100 mm separation from power cables
– Implement proper grounding practices to minimize EMI
- Environmental Considerations:
- Maintain ambient temperature within -20°C to +60°C range
- Ensure adequate ventilation around converter
- Protect from excessive moisture, dust, and corrosive agents
- Safety Precautions:
- Disconnect power before making any connections
- Verify proper isolation between circuits
- Follow lockout/tagout procedures during maintenance
Troubleshooting Guide:
| Symptom | Possible Cause | Recommended Action |
|———|————–|——————-|
| No output signal | Power supply disconnected | Verify 24V AC/DC supply connections |
| Inaccurate readings | Incorrect configuration | Check DIP switch settings and recalibrate |
| Intermittent operation | Loose connections | Tighten terminal screws and check wiring |
| Overheating | Excessive ambient temperature | Improve ventilation or reduce load |
4.3 Maintenance Requirements
Preventive Maintenance Schedule:
– Monthly: Visual inspection for physical damage or corrosion
– Quarterly: Verify calibration accuracy using reference standards
– Annually: Complete functional test and recalibration if necessary
– As Needed: Clean terminals and check for proper connection torque
Calibration Interval Recommendations:
– Critical Applications: Recalibrate every 6 months
– Standard Industrial Use: Recalibrate annually
– Non-critical Monitoring: Recalibrate every 2 years
5. Alternative Model Recommendations
5.1 Direct Alternatives within CC-U Series
ABB 1SVR040001R0400 (CC-U/STD)
– Supply Voltage: 110-240 VAC / 100-300 VDC
– Input Ranges: 28 configurable ranges (16 standard + 12 non-standard)
– Applications: Higher voltage industrial systems
– Advantages: Wider input configuration options, higher supply voltage range
ABB 1SVR040012R2600 (CC-U/RTDR)
– Features: Temperature/resistance signal conversion with relay outputs
– Applications: Temperature monitoring systems with threshold control
– Advantages: Integrated relay outputs for direct control functions
5.2 Cross-Manufacturer Alternatives
Siemens 6EP1336-3BA00
– Type: Signal conditioner/converter
– Input: 0-5 A AC/DC
– Output: 4-20 mA or 0-10 V
– Advantages: Siemens ecosystem integration, TIA Portal compatibility
Phoenix Contact MINI MCR-SL-UI-5A
– Dimensions: Compact 6.2 mm width
– Input: 0-5 A AC/DC
– Output: 0-10 V or 0-20 mA
– Advantages: Ultra-compact design, high density mounting
Weidmüller WIPL 5 AC 24
– Isolation: 4 kV test voltage
– Accuracy: ±0.2% of full-scale
– Features: Integrated diagnostics and status indication
– Advantages: High accuracy, advanced diagnostic capabilities
5.3 Technology-Based Alternatives
Hall Effect-Based Solutions:
– LEM LAH Series: Closed-loop current sensors for industrial applications
– Honeywell CSLT Series: High-accuracy current transducers
– Applications: Precision measurement, high-frequency response requirements
Rogowski Coil Alternatives:
– PEM CWT Series: Flexible current transducers for large conductors
– Applications: Temporary monitoring, high-current AC measurements
– Advantages: Non-invasive installation, wide frequency range
Fluxgate Technology Solutions:
– Danisense F Series: Ultra-high accuracy current transducers
– Applications: Calibration laboratories, precision measurement systems
– Advantages: Exceptional stability, minimal drift over temperature
5.4 Selection Criteria Matrix
| Requirement | Recommended Solution | Key Considerations |
|---|---|---|
| High Accuracy (±0.1%) | Danisense F Series | Cost premium, calibration requirements |
| Compact Installation | Phoenix Contact MINI MCR | Limited adjustment capabilities |
| Siemens Ecosystem | Siemens 6EP1336-3BA00 | System lock-in considerations |
| Cost Optimization | Generic Hall Effect Sensors | Lower accuracy, reduced features |
| High Isolation (4kV+) | Weidmüller WIPL Series | Space requirements, cost factors |
| Wide Temperature Range | ABB 1SVR040006R0100 | Standard industrial performance |
6. Technical Considerations for System Integration
6.1 Electrical Design Factors
Input Circuit Design:
– Current Transformer Selection: Consider burden voltage and accuracy class
– Shunt Resistor Implementation: Calculate power dissipation and thermal management
– Overcurrent Protection: Implement appropriate fusing or circuit protection
Output Interface Design:
– Load Impedance Matching: Ensure compatibility with receiving equipment
– Signal Conditioning: Consider filtering requirements for noisy environments
– Scaling Adjustments: Configure PLC/DCS input modules for proper scaling
6.2 Environmental Considerations
Industrial Environment Factors:
– Temperature Cycling: Account for thermal expansion/contraction effects
– Vibration Resistance: Select appropriate mounting and securing methods
– Contaminant Protection: Consider sealing requirements for dusty/wet environments
EMC Considerations:
– Radiated Emissions: Implement proper shielding and filtering
– Immunity Requirements: Consider surge protection and transient suppression
– Grounding Strategy: Develop comprehensive grounding system design
6.3 System Integration Best Practices
Wiring Recommendations:
– Separation of Signal Types: Maintain minimum 100 mm separation between power and signal cables
– Cable Routing: Use dedicated cable trays or conduits for different signal categories
– Termination Methods: Use appropriate crimping tools and terminal types
Commissioning Procedures:
– Pre-installation Testing: Verify device functionality before installation
– Systematic Calibration: Follow documented calibration procedures
– Functional Testing: Test complete system operation under controlled conditions
7. Regulatory and Standards Compliance
7.1 International Standards
IEC Standards Compliance:
– IEC 61131-2:2025: Programmable controllers – Equipment requirements and tests
– IEC 61000-6-2:2016: EMC – Immunity for industrial environments
– IEC 61000-6-4:2018: EMC – Emission standards for industrial environments
Regional Standards:
– EN 50178:1997: Electronic equipment for use in power installations
– UL 508: Industrial control equipment safety standard
– CSA C22.2 No.14: Industrial control equipment standards
7.2 Industry-Specific Requirements
Process Industry Compliance:
– Hazardous Area Requirements: ATEX, IECEx certifications if applicable
– Safety Integrity Levels: SIL compliance for safety-related applications
– Quality Management: ISO 9001 compliance for manufacturing processes
8. Conclusion and Recommendations
8.1 Summary of Key Findings
The ABB 1SVR040006R0100 Universal RMS Current Converter represents a robust, configurable solution for industrial current measurement applications. Key advantages include:
- Flexible Configuration: 41 output ranges and dual input range selection
- Robust Performance: ±0.5% accuracy, 150 ms response time, -20°C to +60°C operating range
- Safety Features: 3-way electrical isolation, short-circuit proof outputs
- Standards Compliance: Meets IEC, EN, UL, and CSA requirements
8.2 Application-Specific Recommendations
For Motor Control Applications:
– Implement additional filtering for PWM-driven motor currents
– Consider thermal monitoring for continuous high-current operation
– Use shielded cables with proper grounding for signal integrity
For Energy Management Systems:
– Regular calibration to maintain measurement accuracy
– Implement redundant measurement channels for critical applications
– Consider environmental factors affecting long-term stability
For Process Control Instrumentation:
– Validate compatibility with existing control system interfaces
– Establish preventive maintenance schedules
– Document calibration history and performance data
8.3 Future Considerations
Technology Trends:
– Integration with Industrial IoT platforms
– Digital communication interfaces (Modbus, Profinet, EtherCAT)
– Predictive maintenance capabilities through embedded diagnostics
Market Developments:
– Increasing demand for high-accuracy measurement in renewable energy
– Growth in electric vehicle infrastructure requiring precise current monitoring
– Expansion of smart grid technologies driving transducer innovation
9. References
- ABB. (2025). CC-U/I Universal Signal Converter Technical Documentation. ABB Library.
- International Electrotechnical Commission. (2025). IEC 61131-2:2025 – Programmable controllers – Part 2: Equipment requirements and tests.
- RS Components. (2025). ABB 1SVR040006R0100 Product Specifications. https://export.rsdelivers.com/product/abb/1svr040006r0100/abb-signal-conditioner/5117490
- LEM Corporation. (2025). Current Sensor Technology Overview. https://www.lem.com/en/current-sensors
- Fortune Business Insights. (2025). Current Transducer Market Analysis. https://www.fortunebusinessinsights.com/industry-reports/current-transducer-market-101083
- Swartz Engineering. (2025). Current Transducers Working Principles and Applications. https://www.swartzengineering.com/blog/current-transducers-working-principles-types-and-applications
- DIN Standards. (2025). IEC/EN 60715 – Dimensions of low-voltage switchgear and controlgear.
- ABB Measurement & Analytics. (2025). Signal Conditioners and Converters Product Line Overview.
10. Document Information
Revision History:
– Version 1.0: Initial Release – February 2, 2026
– Prepared by: Industrial Automation Technical Team
– Review Status: Technical Review Completed
Disclaimer:
This document is provided for informational purposes only. Specifications are subject to change without notice. Always refer to the manufacturer’s current documentation for the most accurate and up-to-date information. Ensure compliance with all applicable local, regional, and national regulations and standards.
Contact Information:
For technical inquiries or additional information, consult the official ABB technical support channels or authorized distributors.